584 CHAPTER 2: CUDA 12000 BASE SYSTEM COMMANDS
sync-interval
Specifies the time interval between SYNC message transmission on the downstream port.
Mode
interface:cable:csi(<c/s/i>)
Syntax
sync-interval <value>
Arguments
Example
Related Commands
show interface cable <c/s/i> mac on page 421
show mac on page 454
<value> Time, in milliseconds, between downstream SYNC message
transmission. Range: 1 to 200 milliseconds. Default: 5 milliseconds.
cli:172.16.19.10:root# interface 1/1/1
mode: interface:cable:csi(1/1/1)
cli:172.16.19.10:interface:cable:csi(1/1/1)# sync-interval 200
cli:172.16.19.10:interface:cable:csi(1/1/1)# show mac | include "Sync Interval"
Sync Interval 200 (millisec)
cli:172.16.19.10:interface:cable:csi(1/1/1)#