280 CHAPTER 2: CUDA 12000 BASE SYSTEM COMMANDS
no pos flag
Use this command to remove the setting of the following overhead byte values:
c2 — This byte serves as a signal label and indicates the content held within the synchronous
payload envelope (SPE) of the SONET frame, as well as the status of that payload.
J0The section trace byte required for interoperability with some SDH devices in Japan.
Use the pos flag command to configure these SONET overhead byte values.
Mode
interface:pos:csi(<c/s/i>)
Syntax
no pos flag {c2 | j0} <value>
Arguments
Example
cli# interface 1/3/1
mode: interface:pos:csi(1/3/1)
cli# no pos flag c2
cli#
Related Commands
interface on page 181
pos flag on page 316
show interface pos on page 437
c2 <value> Path signal identifier used to identify the payload content type.
Valid range: 0 – 255.
j0 <value> Section trace byte. For interoperability with SDH equipment.
Valid range: 0 – 255.