ADC Cuda 12000 Informations techniques Page 163

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 652
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 162
Cuda 12000 IP Access Switch CLI Reference Guide
event-config reporting 159
event-config reporting
Controls how different classes of events are reported, as required by DOCSIS 1.1. For example,
you can specify that all events in the alert class are sent to the syslog and to SNMP management
stations (in the form of traps).
Mode
root
Syntax
event-config reporting {default | {{emergency | alert | critical |
error | warning | notice | info | debug} {none | local |
local|traps | local|syslog | local|syslog|traps}}
Arguments
default Specifies the default reporting configuration:
emergency – local
alert – local
critical – local|syslog|traps
error – local|syslog|traps
warning – local|syslog|traps
notice – local|syslog|traps
info – none
debug – none
Event Classes:
emergency Specifies the emergency event class, which is the event class with the
highest priority (that is, the most severe events). Events in this class are
reserved for fatal hardware or software errors that prevent normal system
operation and cause the device to reboot.
alert Specifies the alert event class, which is the event class with the second
highest priority. Events in this class indicate a serious failure that causes the
device to reboot, but are not caused by hardware or software
malfunctioning.
Vue de la page 162
1 2 ... 158 159 160 161 162 163 164 165 166 167 168 ... 651 652

Commentaires sur ces manuels

Pas de commentaire