MYXPM6021*
Revision 1.1 - 10/21/14
*Advanced information. Subject to change without notice.
87
MYXPM6021*
Form #: CSI-D-685 Document 011
16 External Battery Charger Control
16.1 Overview
ThePMIChastheabilitytocontrolanexternalbatterychargerIC.Inordertodeterminetheappropriateinputcurrentlimit
forthechargerduringcertainscenarios,theCHGDET_Bpinisassertedorde-assertedbytheUSBPHYontheplatform
dependingonoutputcurrentcapabilityoftheUSBchargerdetected.
ILIM0andILIM1pinsofMYXPM6021willoutputsignalstothechargertosetthechargerinputcurrentlimit.Theexternal
chargeriscapableofgeneratinganinterruptwhichwillbeforwardedtotheSoCviaMYXPM6021.Thisinterruptwillcome
fromtheCHGRINT_Bpin.Duringchargingthebatterytemperaturewillbemonitored.
16.2 Charger Current Limit
Theexternalchargerinputcurrentlimitsaresetaccordingtothetablebelow.
Table 54: External Charger Current Limits
CHRDET_B ILIM1 ILIM0 Power Source Input Current Limit
1 0 0 USB DCP More than 100mA, usually 1.5A
1 0 1 USB SDP 100mA
1 1 1 USB SDP 500mA
X 1 0 AC/DC Adapter Customer specic, limited by max
charger output current
TheAC/DCadapterusuallytakespriorityovertheUSBchargerasinputpowertotheexternalbatterycharger.However,
MYXPM6021detectstheAC/DCadapterbymonitoringVDCIN_SENSE.MYXPM6021changesILIM0andILIM1level
immediatelyVDCIN_SENSEfallbelowtheinternalvoltagereferencethresholdtoinformtheexternalchargertolowerits
currentlimitattheremovalofAC/DCadapter.
Table 55: Charger Control Pins
Name Dir Voltage Signal Description
CHGRINT_B I VSYS Battery charging status and fault interrupt from
charger IC, active low. Internal 10kOhm pull-up to VSYS.
0=interrupt, asserted with a minimum pulse width of 200μs
ILIM[1:0] O VSYS External charger input current limits
CHGDET_B I VUSBPHY USB DCP detection. Asserted by USBPHY when it detected a
charger that can source more than 100mA
Internal 100kOhm pull-up to VSYS
1=SDP detected
0=DCP or CDP/ACA