MYXPM6021*
Revision 1.1 - 10/21/14
*Advanced information. Subject to change without notice.
78
MYXPM6021*
Form #: CSI-D-685 Document 011
Events Condition to be Fullled Comments
Battery Becomes Valid BATLOW_B = 1
ADPWAKEEN = 1
Battery present. AC/DC insertion event
(DCBOOT = 0). The wakeup is only
delayed till battery is charged enough
(VBAT > BATLOW).
BATLOW_B = 1
USBWAKEEN = 1
Battery present. USB insertion event.
The wakeup is only delayed till battery is
charged enough.
Power Button BATLOW_B = 1 System running on battery
PWRBTNWAKE.USBWAKE = 01
PWRBTNWAKE.USBWAKE = 10
Battery present and charging from USB.
Battery still not charged enough.
01 = Wakeup due to DCP charging
source.
11 = Wakeup due to SDP (500mA)
source.
If the battery can only source 100mA,
then the system will not boot.
PWRBTNWAKE.ACDCWAKE = 1
DCBOOT = 0
Battery present and charging from AC/
DC. Battery still not charged enough.
DCBOOT = 1
BSTRMDETRN = 0
Wakeup immediately
12.8 MYXPM6021 Catastrophic and Critical Events
Thereare9“catastrophicandcriticalevents”whichmayforceanimmediateColdOff,i.e.forceanimmediatehardware-
controlledVRshutdown,orsimplyalerttheSOC.Fouroftheseevents–BCUVCRIT,BATRM,SystemTEMPandbattery
TEMP–mayhavecongurableaction,programmedviatheI2Cregistermap.Theseeventsaresplitintotwocategories:
“Catastrophic”and“Critical”Catastrophiceventsare:
• THERMTRIP_B-TheSOCassertsTHERMTRIP_BinresponsetoanSOCover-temperaturecondition.
MYXPM6021assertsSDWN_Bimmediately.After90us,shutsdownallVRs.
• PMICTEMP–MYXPM6021detectsacriticalover-temperatureconditiononitsinternaldiesensorandasserts
SDWN_Bimmediately.After90us,shutsdownallVRs.
• SystemTEMP–MYXPM6021detectsacriticalover-temperatureconditiononanexternalsystemthermistor.If
programmedMYXPM6021assertsSDWN_Bimmediately.After90us,shutsdownallVRs.
• BatteryTEMP–MYXPM6021detectsacriticalover-temperatureconditiononanexternalbatterythermistor.If
programmedMYXPM6021assertsSDWN_Bimmediately.After90us,shutsdownallVRs.
• VSYSUVP–MYXPM6021detectsVSYS“undervoltage”(VSYS≤2.7V)byVSYSundervoltagehard-coded
comparatorformorethan100μs.MYXPM6021assertsSDWN_Bimmediately.After90us,shutsdownallVRs.
• VSYSOVP–MYXPM6021detectsVSYS“overvoltage”(VSYS≥5.4Vmin)byVSYSovervoltagehard-coded
comparatorformorethan100μs.MYXPM6021assertsSDWN_BtogetherwithshuttingdownallVRsimmediately.
Table49:SystemWake-UpCondition(continued)