Figure 32: Battery Single Wire Block Diagram for Analog Sensing, Digital Communication
Table 44: BATID Electrical Specication
Parameter Min Nom Max Units Notes
Frequency 3.268 250 kHz Digital communication
Voltage 1.71 1.8 1.89 V
Vil 0.35 V
Vih 0.9 V
Vhys 0.05 V
Vol 0.01 V 1mA source current
Cload 380 pF
Trise 500 ns 0V to Vih(min)
Tfall 500 ns Vpu to Vil(max)
12.2.3 Battery Presence Detection
NormallytheBSIresistorwillpullthevoltageontheBATIDlinetoalevelthatislowerthanasettrippoint.Ifthebatteryis
removed,theBATIDnodewillbepulledhighbytheR
MBI
platformresistorwhichistypicallyintherangeof30KΩto200KΩ.
Whenthisoccurs,MYXPM6021detectsthatthebatteryisbeingremoved(ifcongured).
Theintegrated100msde-bouncelogicensurestherearenofalseremovalalerts.DependingontheMYXPM6021setting
eitheracompleteColdOffsequencewillbeperformedoraninterrupttotheSOCwillbesent.
IftheDBIENbitbeset,allowingdigitalbatterycommunicationmodetobeenteredontheBATIDpin,thebatterypresence
logicisswitchedofftoavoidbatteryremovaldetection.PriortoDigitalBatteryCommunication,MYXPM6021retainsthe