ADC H2TU-C-319 Manuel d'utilisateur Page 55

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 88
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 54
LTPH-UM-1049-02, Issue 2 Monitoring System Activity and Performance
H2TU-C-319 List 4E January 9, 2002 47
Table 18. HDSL2 Alarm Descriptions
Screen Alarm Front-Panel Alarm Description
MTAE MTAE Metallic Test Access EquipmentThe H2TU-C is in its MTA/LOSW test state.
MTAF MTAF Metallic Test Access FacilityThe H2TU-C is in its MTA/LOSW test state.
LOSW LOSW Loss of Sync WordThe HDSL2 loop has lost synchronization.
MAL xxx-MAL MarginThe margin on the HDSL2 loop has dropped below the minimum threshold value
set for the system. (xxx denotes either TUC or TUR.)
LA xxx-LA Loop AttenuationThe attenuation on the HDSL2 loop has exceeded the maximum value
set for the HDSL2 loop attenuation threshold. (xxx denotes either TUC or TUR.)
HBER xxx-HBER Block Error RateThe HDSL2 BER has exceeded the set threshold limits of 10
-6
or 10
- 7
.
(xxx denotes either TUC or TUR.)
SHORT
(a)
PWR FEED SHRT Indicates a short between the Tip and Ring of the HDSL2 pair.
GND
(a)
(a) Displays only on the H2TU-C HDSL2 interface.
PWR FEED GND The HDSL2 loop is grounded.
OPEN
(a)
PWR FEED OPEN Indicates a line power open condition.
Vue de la page 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 87 88

Commentaires sur ces manuels

Pas de commentaire