Table 19: B8ZS HDSL Spans - Maintenance
Required Tests General Information Parameters
Pulse (Attenuation) HDSL card reading at customer
premises
ADC/Pairgain
0 to -28 DB
(Each link when doublers are used.)
Adtran HDSL and HDSL2
0 to -30 DB
(Each link when doublers are used.)
Adtran HDSL4
0 to -35 dB (No regenerator or 1st link ( CO to regenerat-
or))
0 to -31 dB (Regenerated signal 2nd link (regenerator to
premise.))
Signal to Noise Margin HDSL card reading at customer
premises
ADC/Pairgain or Adtran
6 or greater
Signal Level HDSL card reading at customer
premises
ADC/Pairgain or Adtran
0 to -7.5 DB
Note: 0 DB level may be as high as +1.6 DB
QRSS
1 five minute test
test pattern 0 errors
1 in 8
1 two minute test
test pattern 0 errors
All Ones
1 two minute test
test pattern 0 errors
All Zeros
1 thirty second test
test pattern 0 errors
Special Note: For Adtran HDSL2 cards used in a Litespan system. Although the Adtran card is shipped with a line
code of B8ZS, the Litespan will change that value to the Litespan automatic default of AMI. The Central Office, NOC or
AT&T Practice ATT-TP-000-000-006
Issue 1, 08/25/06
2006 AT&T Knowledge Ventures. All rights reserved