Specification 7060
(A) TPC-14-GY-5K-ROM *14 .21” 29 lbs./1,000’
TPC-12-GY-5K-ROM *12 .23” 40 lbs./1,000’
TPC-10-GY-5K-ROM *10 .26” 56 lbs./1,000’
TPC-8-GY-5K-ROM *8 .31” 87 lbs./1,000’
TPC-6-GY-5K-ROM *6 .35” 124 lbs./1,000’
TPC-4-GY-5K-ROM *4 .40” 180 lbs./1,000’
TPC-2-GY-5K-ROM *2 .46” 265 lbs./1,000’
TPC-1/0-GY-5K-ROM *1/0 .58” 425 lbs./1,000’
TPC-2/0-GY-5K-ROM *2/0 .62” 520 lbs./1,000’
TPC-4/0-GY-5K-ROM *4/0 .73” 785 lbs./1,000’
TPC-350-GY-2.5K-ROM *350 .93” 1270 lbs./1,000’
TPC-500-GY-2K-ROM *500 1.05” 1770 lbs./1,000’
TPC-750-GY-2K-ROM *750 1.26” 2645 lbs./1,000’
Specification 7070
TPCL-14-GY-5K-ROM *14 .21” 29 lbs./1,000’
TPCL-12-GY-5K-ROM *12 .23” 40 lbs./1,000’
TPCL-10-GY-5K-ROM *10 .26” 56 lbs./1,000’
TPCL-8-GY-5K-ROM *8 .31” 87 lbs./1,000’
TPCL-6-GY-5K-ROM *6 .35” 124 lbs./1,000’
TPCL-4-GY-5K-ROM *4 .41” 184 lbs./1,000’
TPCL-2-GY-5K-ROM *2 .47” 271 lbs./1,000’
TPCL-1/0-GY-5K-ROM *1/0 .59” 434 lbs./1,000’
TPCL-2/0-GY-5K-ROM *2/0 .64” 532 lbs./1,000’
TPCL-4/0-GY-5K-ROM *4/0 .75” 806 lbs./1,000’
TPCL-350-GY-2.5K-ROM *350 .95” 1290 lbs./1,000’
TPCL-500-GY-2K-ROM *500 1.08” 1790 lbs./1,000’
TPCL-750-GY-2K-ROM *750 1.29” 2666 lbs./1,000’
Specification 7076
TPCLF-8-GY-5K-ROM 8 .33” 100 lbs./1,000’
TPCLF-6-GY-5K-ROM 6 .38” 140 lbs./1,000’
TPCLF-4-GY-5K-ROM 4 .44” 215 lbs./1,000’
TPCLF-2-GY-5K-ROM 2 .50” 305 lbs./1,000’
TPCLF-1/0-GY-5K-ROM 1/0 .66” 510 lbs./1,000’
TPCLF-2/0-GY-5K-ROM 2/0 .70” 577 lbs./1,000’
TPCLF-4/0-GY-5K-ROM *4/0 .82” 847 lbs./1,000’
TPCLF-350-GY-2.5K-ROM *350 1.04” 1377 lbs./1,000’
TPCLF-500-GY-2K-ROM *500 1.22” 1920 lbs./1,000’
TPCLF-750-GY-2K-ROM *750 1.52” 2800 lbs./1,000’
Nominal Outside Approx. Net
Catalog # Size Diameter Weight/Length
*Items are considered stock items for Rome Cable.
Specification 7060:
HYPALON insulation, cotton braid, gray saturant-finish Type RHH or RHW,
VW-1, oil resistant II and sun resistant for CT use
Specification 7070:
Low-smoke, non-halogen, elastomeric insulation, cotton braid, Type RHH or RHW,
limited-smoke and sun resistant for CT use
Specification 7076:
•Flexible conductor, low-smoke, non-halogen, elastomeric insulation, cotton braid, Type
RHH or RHW, limited-smoke and sun resistant for CT use
A
Central Office Cable
ROME TELEPHONE POWER CABLE, 600V
Install this general purpose wiring in telephone Central Office power plants
within raceway, or on racks or trays since the gray finish harmonizes with the
color of other telephone equipment. Cables are rated 90C degrees in dry
locations and 75C degrees in wet locations at a maximum circuit voltage of 600V.
In addition to the constructions listed below, Rome telephone power cable also
comes in Specification 7064 (8 AWG – 1,000MCM Flex conductor, HYPALON
®
insulation and no cotton braid) and Specification 7066 (8 AWG – 750MCM Flex
conductor, HYPALON insulation and cotton braid).