LSA-PLUS
®
Series 2 & avaNTi Modules and Accessories
LSA-PLUS
®
TECHNICAL DATA
Disconnection, Connection, Switching and Earth Modules for Plastic Insulated Copper Conductors
Copper Conductor Diameter
0.40 - 0.80mm. (AWG 26 - 20)
Multistrand Conductor 7/0.2 - 7/0.32mm
Insulation Diameter 0.70 - 1.50mm
Number of Equal Diameter 2 max. (up to 0.65mm each)
Solid Conductors Per Slot
Number of Equal Diameter
1 max.
Multistrand Conductors Per Slot
ENVIRONMENTAL DATA
Environment for use
Indoors or enclosed cabinets outdoors with a
minimum degree of protection to IP54 (IEC-529)
Storage temperature -40° to +90°C
Operating temperature -20° C - +80° C
Max. operating humidity 93% relative humidity non-condensing
LSA-PLUS
®
ELECTRICAL DATA
After four days exposure to a climate of 40° C and 93% relative humidity
Insulation Resistance
≥5x10
4
Ohms
Dielectric Strength ≥2000Vrms
Current Rating ≥Current carrying capacity of terminated
conductor
LSA-PLUS
®
CONTACT
Contact Resistance
1mΩ ≤ 5mΩ guaranteed
Total Contact Resistance including
Disconnection contacts ≤ 10mΩ
Contact Spring Force for Disconnecting 3N (approx. 300g)
contacts
Peak voltage
(with pulses 1.2/50µ sec)
≥ 3.6 V
Impulse current
(with pulses 8/20 µ sec)
5 kA
Number of Re-Terminations ≥200
Coupling Capacitance Between Wires. ≤1pF
Plastic Housing Material Thermoplastic (PBT) UL 94, V-0
Oxygen Index ≥28%