Page 1 - USER MANUAL

HiGainHiGainUSER MANUAL2H2TU-C-231 List 2 Line UnitProduct Catalog: H2TU-C-231-L2CLEI: VACJDLYE

Page 2 - LTPH-UM-1109-01, Issue 1

Overview LTPH-UM-1109-01, Issue 12 January 9, 2002 H2TU-C-231 List 2– Remote provisioning– Selectable loopback activation codes• Additional (Loopback

Page 3 - INSPECTING SHIPMENT

LTPH-UM-1109-01, Issue 1 Front PanelH2TU-C-231 List 2 January 9, 2002 3FRONT PANELFigure 1 shows the H2TU-C-231 List 2 front panel. Table 1 on page 4

Page 4

Front Panel LTPH-UM-1109-01, Issue 14 January 9, 2002 H2TU-C-231 List 2Table 1. Front-Panel DescriptionFront-Panel Feature FunctionFront-panel display

Page 5 - TABLE OF CONTENTS

LTPH-UM-1109-01, Issue 1 Front PanelH2TU-C-231 List 2 January 9, 2002 5Table 2 lists the front-panel display messages. The four-character display repo

Page 6

Front Panel LTPH-UM-1109-01, Issue 16 January 9, 2002 H2TU-C-231 List 2NREM Network Remote Loopback DSX-1 signal is looped back to the network at the

Page 7 - LIST OF FIGURES

LTPH-UM-1109-01, Issue 1 InstallationH2TU-C-231 List 2 January 9, 2002 7INSTALLATIONFigure 2. Installing the H2TU-C-231 List 2 into a Shelf1 Align the

Page 8 - LIST OF TABLES

Installation LTPH-UM-1109-01, Issue 18 January 9, 2002 H2TU-C-231 List 2VERIFICATIONOnce the H2TU-C-231 is installed, verify that it is operating prop

Page 9 - OVERVIEW

LTPH-UM-1109-01, Issue 1 ProvisioningH2TU-C-231 List 2 January 9, 2002 9PROVISIONINGThere are two methods for provisioning:• Use the MODE and SEL push

Page 10 - APPLICATIONS

Provisioning LTPH-UM-1109-01, Issue 110 January 9, 2002 H2TU-C-231 List 2Resetting to Factory Default ValuesAlluseroptionsfortheH2TU-C-231List2(Table

Page 11 - FRONT PANEL

LTPH-UM-1109-01, Issue 1 ProvisioningH2TU-C-231 List 2 January 9, 2002 11USING A MAINTENANCE TERMINALConnecting to a Maintenance TerminalThe craft por

Page 12

LTPH-UM-1109-01, Issue 1ii January 9, 2002 H2TU-C-231 List 2Revision History of This PracticeCopyrightJanuary 9, 2002© 2002 ADC DSL Systems, Inc. All

Page 13

Provisioning LTPH-UM-1109-01, Issue 112 January 9, 2002 H2TU-C-231 List 2Figure 3. Logon ScreenMost VT100 emulation programs support a print screen op

Page 14 - 3 or more seconds

LTPH-UM-1109-01, Issue 1 ProvisioningH2TU-C-231 List 2 January 9, 2002 13PROVISIONING TASKSAfter H2TU-C-231 is successfully installed, perform these b

Page 15 - INSTALLATION

Provisioning LTPH-UM-1109-01, Issue 114 January 9, 2002 H2TU-C-231 List 24 Type the time in the format indicated (entering seconds is optional), then

Page 16 - VERIFICATION

LTPH-UM-1109-01, Issue 1 ProvisioningH2TU-C-231 List 2 January 9, 2002 15Configuring the SystemTheConfigmenu(Figure 6) allows you to make the followin

Page 17 - PROVISIONING

Provisioning LTPH-UM-1109-01, Issue 116 January 9, 2002 H2TU-C-231 List 2Figure 7. Config Menu - Standard Options (defaults shown)Figure 8. Config Men

Page 18 - Disabling an Alarm

LTPH-UM-1109-01, Issue 1 ProvisioningH2TU-C-231 List 2 January 9, 2002 17Table 5 describes the Standard Config menu options and Table 6 on page 18 des

Page 19 - USING A MAINTENANCE TERMINAL

Provisioning LTPH-UM-1109-01, Issue 118 January 9, 2002 H2TU-C-231 List 2H2TU-R Line BuildoutRLBO Sets the DS1 receive level output toward the Custome

Page 20 - Table 4. Logon Screen Menus

LTPH-UM-1109-01, Issue 1 ProvisioningH2TU-C-231 List 2 January 9, 2002 19DS1 Line Coding (DS1) Option. The DS1 line code option should always be set t

Page 21 - PROVISIONING TASKS

Provisioning LTPH-UM-1109-01, Issue 120 January 9, 2002 H2TU-C-231 List 2H2TU-C Equalization (EQL) Option. The equalizer shapes the DS1 output signal

Page 22 - Setting Circuit ID Numbers

LTPH-UM-1109-01, Issue 1 ProvisioningH2TU-C-231 List 2 January 9, 2002 21DS1 BER (DBER) Option. The DS1 BER alarm occurs when any of the DS1 or DSX-1

Page 23 - Configuring the System

LTPH-UM-1109-01, Issue 1 Using This ManualH2TU-C-231 List 2 January 9, 2002 iiiUSING THIS MANUALThe following conventions are used in this manual:• Mo

Page 24

Provisioning LTPH-UM-1109-01, Issue 122 January 9, 2002 H2TU-C-231 List 2Resetting to Factory DefaultsTo reset the H2TU-C-231 List 2 to its original f

Page 25

LTPH-UM-1109-01, Issue 1 ProvisioningH2TU-C-231 List 2 January 9, 2002 23Clearing the History, Alarm, and Event Log ScreensSelect Master Clear to clea

Page 26

Monitoring System Activity and Performance LTPH-UM-1109-01, Issue 124 January 9, 2002 H2TU-C-231 List 2MONITORING SYSTEM ACTIVITY ANDPERFORMANCEThe HD

Page 27

LTPH-UM-1109-01, Issue 1 Monitoring System Activity and PerformanceH2TU-C-231 List 2 January 9, 2002 253 To initiate a loopdown of all active loopback

Page 28

Monitoring System Activity and Performance LTPH-UM-1109-01, Issue 126 January 9, 2002 H2TU-C-231 List 2USING THE PERFORMANCE SCREENS TO VIEW PERFORMAN

Page 29 - UAS-P, UAS-L 10

LTPH-UM-1109-01, Issue 1 Monitoring System Activity and PerformanceH2TU-C-231 List 2 January 9, 2002 27Figure 13. H2TU-C DS1 48-Hour Performance Histo

Page 30 - Resetting to Factory Defaults

Monitoring System Activity and Performance LTPH-UM-1109-01, Issue 128 January 9, 2002 H2TU-C-231 List 2Examples of current statistics screens are show

Page 31

LTPH-UM-1109-01, Issue 1 Monitoring System Activity and PerformanceH2TU-C-231 List 2 January 9, 2002 29Table 9. Acronyms Used on the DS1 Performance H

Page 32 - PERFORMANCE

Monitoring System Activity and Performance LTPH-UM-1109-01, Issue 130 January 9, 2002 H2TU-C-231 List 2Performance History at the HDSL2 InterfaceThe H

Page 33 - SPACEBAR ENTER N

LTPH-UM-1109-01, Issue 1 Monitoring System Activity and PerformanceH2TU-C-231 List 2 January 9, 2002 31Figure 19. H2TU-C HDSL2 25-Hour Performance His

Page 34 - SPACEBAR

Inspecting Shipment LTPH-UM-1109-01, Issue 1iv January 9, 2002 H2TU-C-231 List 2

Page 35

Monitoring System Activity and Performance LTPH-UM-1109-01, Issue 132 January 9, 2002 H2TU-C-231 List 2USING THE PERFORMANCE SCREENS TO VIEW ALARM DAT

Page 36

LTPH-UM-1109-01, Issue 1 Monitoring System Activity and PerformanceH2TU-C-231 List 2 January 9, 2002 33Alarm History at the DS1 InterfaceThe Alarm His

Page 37

Monitoring System Activity and Performance LTPH-UM-1109-01, Issue 134 January 9, 2002 H2TU-C-231 List 2Table 11. DS1 Alarm DescriptionsScreen AlarmFro

Page 38

LTPH-UM-1109-01, Issue 1 Monitoring System Activity and PerformanceH2TU-C-231 List 2 January 9, 2002 35Alarm History at the HDSL2 InterfaceThe HDSL2 A

Page 39

Monitoring System Activity and Performance LTPH-UM-1109-01, Issue 136 January 9, 2002 H2TU-C-231 List 2USING THE SYSTEM EVENT LOG TO TRACK EVENTSTo vi

Page 40

LTPH-UM-1109-01, Issue 1 Monitoring System Activity and PerformanceH2TU-C-231 List 2 January 9, 2002 37USING THE REPORT MENUThe Report menu (Figure 25

Page 41

Monitoring System Activity and Performance LTPH-UM-1109-01, Issue 138 January 9, 2002 H2TU-C-231 List 2Table 13. Report TypesType Contains the followi

Page 42

LTPH-UM-1109-01, Issue 1 Monitoring System Activity and PerformanceH2TU-C-231 List 2 January 9, 2002 39Table 14. Event Log Entry Messages ListEvent Lo

Page 43

Testing LTPH-UM-1109-01, Issue 140 January 9, 2002 H2TU-C-231 List 2TESTINGThis section provides information about front-panel system alarms, LOS and

Page 44

LTPH-UM-1109-01, Issue 1 TestingH2TU-C-231 List 2 January 9, 2002 41Alarm Option for Digital Loop Carrier (DLC) FeedTo improve HiGain HDSL2 compatibil

Page 45 - Report Type : Full Report

LTPH-UM-1109-01, Issue 1 Table of ContentsH2TU-C-231 List 2 January 9, 2002 vTABLE OF CONTENTSOverview _______________________________________________

Page 46 - Table 13. Report Types

Testing LTPH-UM-1109-01, Issue 142 January 9, 2002 H2TU-C-231 List 2Remote LOS and AIS ResponseFigure 26 shows the different ways the H2TU-R can respo

Page 47

LTPH-UM-1109-01, Issue 1 TestingH2TU-C-231 List 2 January 9, 2002 43LOOPBACK OPERATIONHiGain HDSL2 has a family of loopback options for analyzing circ

Page 48 - SYSTEM ALARMS

Testing LTPH-UM-1109-01, Issue 144 January 9, 2002 H2TU-C-231 List 2Table 16. Summary of HiGain HDSL2 Loopback Codes and Activation MethodsMethod of A

Page 49 - Retiring System Alarms

LTPH-UM-1109-01, Issue 1 TestingH2TU-C-231 List 2 January 9, 2002 45Special Loopback CommandsIn addition to the GNLB loopback command mode, a HiGain H

Page 50 - Remote LOS and AIS Response

Testing LTPH-UM-1109-01, Issue 146 January 9, 2002 H2TU-C-231 List 2Manual Loopback SessionA manual loopback session allows you to select any one of t

Page 51 - Premises

LTPH-UM-1109-01, Issue 1 TestingH2TU-C-231 List 2 January 9, 2002 47• COL? = dual loopback at H2TU-C.• RUL? = dual loopback at H2TU-R.4 Press SEL to a

Page 52

Testing LTPH-UM-1109-01, Issue 148 January 9, 2002 H2TU-C-231 List 24 Have the CO tester send the NLOC (4-in-7) inband loopup for 5 seconds. You shoul

Page 53 - Special Loopback Commands

LTPH-UM-1109-01, Issue 1 TestingH2TU-C-231 List 2 January 9, 2002 49A1LB, A2LB, and A5LB Test ProceduresUsing the codes listed in Table 17, a network

Page 54 - Manual Loopback Session

Testing LTPH-UM-1109-01, Issue 150 January 9, 2002 H2TU-C-231 List 2To perform the A1LB, A2LB, and the A5LB loopback test procedures:1 Send the inband

Page 55 - LOOPBACK TEST PROCEDURES

LTPH-UM-1109-01, Issue 1 TestingH2TU-C-231 List 2 January 9, 2002 51A3LB and A4LB Test ProceduresThe H2TU-C-231 can be looped back by sending the Addr

Page 56 - CI-Customer Interface

Table of Contents LTPH-UM-1109-01, Issue 1vi January 9, 2002 H2TU-C-231 List 2Testing ________________________________________________________________

Page 57

Testing LTPH-UM-1109-01, Issue 152 January 9, 2002 H2TU-C-231 List 2TESTING WITH H2TU-C BERT GENERATORThe H2TU-C BERT Generator screen allows transmis

Page 58

LTPH-UM-1109-01, Issue 1 TestingH2TU-C-231 List 2 January 9, 2002 53TESTING WITH H2TU-R BERT GENERATORThe H2TU-R BERT Generator screen allows transmis

Page 59 - A3LB and A4LB Test Procedures

Appendix A - Specifications LTPH-UM-1109-01, Issue 154 January 9, 2002 H2TU-C-231 List 2APPENDIX A-SPECIFICATIONSPowerHDSL2 Span Voltage 0 or -180 Vdc

Page 60

LTPH-UM-1109-01, Issue 1 Appendix A - SpecificationsH2TU-C-231 List 2 January 9, 2002 55POWER CONSUMPTIONThe three most important power parameters of

Page 61

Appendix A - Specifications LTPH-UM-1109-01, Issue 156 January 9, 2002 H2TU-C-231 List 2LOOP ATTENUATION,INSERTION LOSS, AND REACHEach loop has no mor

Page 62 - APPENDIX A-SPECIFICATIONS

LTPH-UM-1109-01, Issue 1 Appendix A - SpecificationsH2TU-C-231 List 2 January 9, 2002 57H2TU-C-231 LIST 2CARD-EDGE CONNECTORFigure 31 shows the card-e

Page 63 - MAXIMUM CURRENT DRAIN

Appendix A - Specifications LTPH-UM-1109-01, Issue 158 January 9, 2002 H2TU-C-231 List 2Fuse AlarmPin 32 on the card-edge connector is a fuse alarm th

Page 64 - Ω per kft

LTPH-UM-1109-01, Issue 1 Appendix B - Functional OperationH2TU-C-231 List 2 January 9, 2002 59APPENDIX B-FUNCTIONAL OPERATIONADC HDSL2 technology prov

Page 65 - IST 2CARD-EDGE CONNECTOR

Appendix C - Compatibility LTPH-UM-1109-01, Issue 160 January 9, 2002 H2TU-C-231 List 2APPENDIX C-COMPATIBILITYThe HiGain system uses HDSL2 transmissi

Page 66 - RAFT PORT

LTPH-UM-1109-01, Issue 1 Appendix D - Product SupportH2TU-C-231 List 2 January 9, 2002 61APPENDIX D-PRODUCT SUPPORTADC Customer Service Group provides

Page 67 - ROUND FAULT DETECT

LTPH-UM-1109-01, Issue 1 List of FiguresH2TU-C-231 List 2 January 9, 2002 viiLIST OF FIGURES1. H2TU-C-231 List 2 Front Panel...

Page 68 - APPENDIX C-COMPATIBILITY

Appendix E - Abbreviations LTPH-UM-1109-01, Issue 162 January 9, 2002 H2TU-C-231 List 2APPENDIX E-ABBREVIATIONSAACO: Alarm CutoffADSL: Asymmetric Di

Page 69 - APPENDIX D-PRODUCT SUPPORT

LTPH-UM-1109-01, Issue 1 Appendix E - AbbreviationsH2TU-C-231 List 2 January 9, 2002 63LBPV: Local Bipolar ViolationLBTO: Loopback TimeoutLED: Ligh

Page 70 - APPENDIX E-ABBREVIATIONS

Appendix E - Abbreviations LTPH-UM-1109-01, Issue 164 January 9, 2002 H2TU-C-231 List 2

Page 71

CERTIFICATION AND WARRANTYFCC CLASS ACOMPLIANCEThis equipment has been tested and found to comply with the limits for a Class A digital device, pursua

Page 72

ADC DSL Systems, Inc.14402 Franklin AvenueTustin, CA 92780-7013Tel: 714.832.9922Fax: 714.832.9924Technical AssistanceTel: 800.638.0031Tel: 714.730.322

Page 73 - CERTIFICATION AND WARRANTY

List of Tables LTPH-UM-1109-01, Issue 1viii January 9, 2002 H2TU-C-231 List 2LIST OF TABLES1. Front-Panel Description...

Page 74 - ISO 9001/TL 9000

LTPH-UM-1109-01, Issue 1 OverviewH2TU-C-231 List 2 January 9, 2002 1OVERVIEWThe H2TU-C-231 List 2 line unit is the Central Office (CO) side of a T1 tr

Commentaires sur ces manuels

Pas de commentaire